Start a project

Light isa buildingmaterial.

Benamu Lighting designs, calculates and manufactures lighting for architectural, commercial, industrial and cultural spaces.

Volume Space
A dark section through a space, lit by the beam cone of a luminaire mounted in the ceiling. 35°
A volume is only a dimension until light is placed in it. Where that light lands, at what angle and at what intensity, is the decision that builds the space.

More than a luminaire supplier

Most projects leave lighting until last and pick from a catalogue. We take the requirement from the start: we survey, calculate, draw, and where the project needs it, develop the luminaire and build it on our own line.

Design

A lighting scheme built around how the space is used, what it is made of and how it reads.

Engineering

Optical, thermal and mechanical resolution, driver selection and mounting detail.

Calculation

Numerical verification of illuminance, uniformity, glare and energy density.

Manufacturing

The approved solution becomes a luminaire on our own line, then goes into commissioning.

Applications

Every space asks something different of light

A museum vitrine and a factory hall do not share a luminaire. What separates them is optical distribution, ingress rating, colour rendering and maintenance access.

Illuminance on the working plane, glare control, and an artificial scheme that stays balanced against daylight.

Glare control and colour rendering

Directed light that keeps the building's geometry legible after dark without spilling onto neighbours or the sky.

Weather-rated housings

Low-level lighting that keeps routes safe while bringing planting texture and water surfaces forward.

Light spill and impact resistance

High-efficiency systems for aisle uniformity, tall mounting heights and long maintenance intervals.

Uniformity and maintenance interval

Layered, dimmable comfort lighting that adapts to scenes changing through the day.

Layered scenes and dimming

High colour rendering and precise aiming, with the total light dose falling on the object kept under control.

UV and cumulative exposure

A luminaire passes seven stations before it reaches a space

This is the route a project-specific luminaire takes. Where a project selects from a catalogue the first three stations shorten; the rest do not change.

01

Requirement

The architectural drawings, the use of the space and the target illuminance are read. Constraints settle here: ceiling type, mounting depth, supply and budget.

Drawings and site

02

Sketch

The relationship between luminaire and space is worked out by hand. Body proportion, light-emitting surface and visible detail are decided at this stage.

Proportion and form

03

Technical drawing

The sketch becomes a dimensioned drawing. Housing, optic seat, driver volume and mounting interface are made ready for manufacture.

Dimensions and tolerance

04

Lighting calculation

Photometric data is placed into the room model. Illuminance, uniformity and glare are calculated, and luminaire count and position follow from the result.

Photometry and layout

05

Prototype

The first housing is built and measured. Distribution, thermal behaviour and ease of installation are verified against real site conditions.

Measurement and verification

06

Manufacturing

The approved housing goes into production. Machining, assembly, electronics and surface treatment run on our own line.

Machining, assembly, finish

07

Space

Luminaires are installed, aimed and commissioned. Whatever gap remains between the calculation and the site is closed here.

Installation and commissioning

Lighting calculation

Light is not estimated, it is calculated

Luminaire count is not a preference, it is a result. Once room dimensions, surface reflectances, mounting height and target illuminance are on the table, the layout writes itself.

300 lx 400 lx 500 lx 16.00 m 24° h 4.00 m Uo 0.60 UGR 19 Ra 90
  • Luminaire
  • Beam cone
  • Isolux contour
The diagram shows how a lighting calculation is read. The figures are illustrative; every calculation is run against the project's own room model.
Illuminance
lx
Light arriving at the working plane. The function of the space sets the target.
Uniformity
Uo
Minimum over average. It keeps the eye reading the space without interruption.
Glare
UGR
A measure of uncomfortable brightness in the direct field of view.
Colour rendering
Ra
How truly colour reads under the light. Decisive in display and retail.
Beam angle
°
The spread of the light. It separates accent from general lighting.
Energy density
W/m²
Installed load per unit area. The indicator of efficiency and running cost.

Calculate your own room

Standard is not always enough

On some projects the right luminaire is not in the catalogue. The ceiling detail does not accept it, the beam angle does not reach, the housing does not speak to the architecture. That is where we develop the product for the project itself.

Architectural detail

When the luminaire has to disappear into a reveal, a niche or a soffit.

Optical requirement

When the intended distribution cannot be met by an off-the-shelf reflector or lens.

Scale

When the size of the space makes catalogue proportions meaningless.

Ingress conditions

When humidity, salt, impact or temperature exceed what a standard housing allows.

Bespoke design is not a departure from series production. The same engineering and the same line are set up around a single project's requirement.

Bespoke design

Manufacturing

Designed. Calculated. Manufactured.

Manufacturing lighting means turning a drawing into material. Keeping design, calculation and production under one roof is what lets a problem found on site travel back to the drawing table.

  1. 01

    Product development

    Housing, optics and thermal solution matured together.

  2. 02

    Machining

    Housings and carriers produced to dimension.

  3. 03

    Assembly

    Optical, electronic and mechanical components brought together.

  4. 04

    Surface treatment

    Surface protection against corrosion and exposure.

  5. 05

    Testing

    Electrical safety and function verified at the end of the line.

The scope of manufacturing varies with the project requirement. Which steps apply to a given project is confirmed in writing at quotation stage.

We work to the desk that writes the specification

We prepare the technical data an architect, interior designer, lighting designer, electrical engineer or contractor needs, on a per-project basis.

These documents are produced for the project and the selected luminaire rather than pulled from a standing archive. Send us your project and we will prepare the relevant files for you.

Technical catalogue

Housing, optical and mounting information for the selected product families.

Product datasheet

Summary electrical and photometric data for the luminaire.

Photometric file

IES and LDT files for use in lighting calculation software.

  • IES
  • LDT
Request

CAD drawing

Dimensioned two-dimensional drawing of the luminaire.

  • DWG
  • DXF
Request

BIM object

Parametric object for placement in the building information model.

  • RFA
  • IFC
Request

Installation document

Placement, supply and aiming instructions.

Let us buildthe spacetogether.

Share your project, your drawings or your technical requirements. We will work out together where the light lands, at what angle and at what intensity.