We work to the desk that writes the specification

We prepare the technical data an architect, interior designer, lighting designer, electrical engineer or contractor needs, on a per-project basis.

Lighting calculation

Light is not estimated, it is calculated

Luminaire count is not a preference, it is a result. Once room dimensions, surface reflectances, mounting height and target illuminance are on the table, the layout writes itself.

300 lx 400 lx 500 lx 16.00 m 24° h 4.00 m Uo 0.60 UGR 19 Ra 90
  • Luminaire
  • Beam cone
  • Isolux contour
The diagram shows how a lighting calculation is read. The figures are illustrative; every calculation is run against the project's own room model.
Illuminance
lx
Light arriving at the working plane. The function of the space sets the target.
Uniformity
Uo
Minimum over average. It keeps the eye reading the space without interruption.
Glare
UGR
A measure of uncomfortable brightness in the direct field of view.
Colour rendering
Ra
How truly colour reads under the light. Decisive in display and retail.
Beam angle
°
The spread of the light. It separates accent from general lighting.
Energy density
W/m²
Installed load per unit area. The indicator of efficiency and running cost.

Calculate your own room

Luminaire types

Luminaires divide by what they do

The types below are grouped by how they distribute light and where they are mounted. Each card carries the distribution drawing and an example of that type from our catalogue.

None of these families is a fixed model list. Wattage, luminous flux, colour temperature, ingress rating and beam angle are set against the project's requirement, and the datasheet is issued to match.

Recessed downlight

The base interior luminaire, recessed into a suspended ceiling and directing light downward. Glare control is resolved through housing depth.

Used in
Interior, Hospitality, Museum and heritage

Track and spot

Accent luminaires whose position and aim can be changed later. The flexible side of display and retail layouts.

Used in
Interior, Museum and heritage

600 x 600 panel

Takes the place of a suspended ceiling tile and spreads light from a large, low-luminance surface. The default answer in offices and teaching spaces.

Used in
Interior, Hospitality

Linear system

Continuous runs that follow the architectural line. Can be recessed into reveals and niches.

Used in
Interior, Warehouse and factory

Ring pendant

A circular body lighting both downward and upward. The form itself becomes a geometric element of the room.

Used in
Interior, Hospitality, Museum and heritage

High bay

High-efficiency industrial luminaires covering large areas from tall mounting heights.

Used in
Warehouse and factory

Facade luminaire

Aimable, sealed-housing luminaires that wash or accent the building envelope.

Used in
Facade and architectural accent, Museum and heritage

Floodlight

High-output sealed-body luminaire aimed at a target, in narrow or wide distributions. For facades, yards and sports areas.

Used in
Facade and architectural accent, Warehouse and factory, Park, garden and landscape

Pole top

Lights a route and its surroundings from the top of a column. Spacing and mounting height, not wattage, decide the uniformity.

Used in
Park, garden and landscape, Facade and architectural accent

Bollard

Exterior luminaires at pedestrian height that keep light directed downward.

Used in
Park, garden and landscape, Facade and architectural accent

In-ground

Walkable recessed luminaires that graze a surface or wash a vertical element from below.

Used in
Park, garden and landscape, Facade and architectural accent

Project-specific

Luminaires developed from scratch where the families above do not meet the requirement.

Used in
Interior, Hospitality, Museum and heritage, Facade and architectural accent

Bespoke design

These documents are produced for the project and the selected luminaire rather than pulled from a standing archive. Send us your project and we will prepare the relevant files for you.

Technical catalogue

Housing, optical and mounting information for the selected product families.

Product datasheet

Summary electrical and photometric data for the luminaire.

Photometric file

IES and LDT files for use in lighting calculation software.

  • IES
  • LDT
Request

CAD drawing

Dimensioned two-dimensional drawing of the luminaire.

  • DWG
  • DXF
Request

BIM object

Parametric object for placement in the building information model.

  • RFA
  • IFC
Request

Installation document

Placement, supply and aiming instructions.

Installation

Installation and electrical safety

The following is general guidance. Electrical installation work must be carried out by a qualified electrician in accordance with the regulations in force.

Electric shock kills. No connection is made before the supply is isolated and the absence of voltage has been confirmed by measurement.

  1. 01

    Isolate the supply and lock it off

    Drop the fuse or breaker for the circuit. Hang a warning label on the board and lock the breaker off where you can. Someone who does not know you are working can put it back on; the label is the only thing preventing that.

  2. 02

    Prove the circuit dead by measurement

    Switching off is not proof. Test your instrument on a known live point, then on the circuit you will work on, then on the known live point again. That final step is the only way you learn the instrument failed in between.

  3. 03

    Identify line, neutral and protective conductor

    The common colour code is brown, black or grey for line, blue for neutral, green-and-yellow for the protective conductor. A colour code is an expectation, not a guarantee: in an old or altered installation, confirm by measurement before trusting it.

  4. 04

    Connect earth first, disconnect it last

    On Class I luminaires the conductive body must be bonded to the protective conductor. Connect earth first and remove it last, so the body is protected at every moment in between.

  5. 05

    Prepare and tighten terminals properly

    A loose terminal heats, and a hot terminal starts fires. No insulation inside the terminal, no bare copper outside it. Use ferrules on stranded conductors rather than clamping them like solid core.

  6. 06

    Never let the cable carry the luminaire

    On pendants and high bays the suspension fixes to structure, not to a ceiling tile or a grid profile. The cable is a conductor, not a support.

  7. 07

    Match ingress protection and driver position to the place

    In wet rooms, outdoors and anywhere pressure-washed, the luminaire's IP rating has to meet the environment. The driver goes somewhere accessible and ventilated, never buried in insulation.

  8. 08

    Final check before energising

    Review the connections and the insulation, measure the continuity of the body bond, refit covers and gaskets. If you will measure after energising, use appropriate personal protective equipment.

This text does not replace any luminaire's own installation document. The manual supplied with the product and the wiring regulations in force take precedence.

Selection

What to weigh when choosing a luminaire

Price and wattage do not define a luminaire. The headings below are the values to look for on a datasheet, and the ones that cause trouble on site when they are skipped.

Illuminance
lx
The function of the space sets the target. Target first, luminaire second; reverse the order and the result is an accident.
Uniformity
Uo
A correct average over an uneven distribution still reads as a blotchy room. Spacing must stay inside the limit the mounting height sets.
Glare
UGR
The most common complaint in offices and teaching spaces. The figure belongs to the luminaire and the room together, so read the conditions a datasheet's UGR was measured under.
Colour rendering
Ra and R9
Ra alone misleads. Whether red looks right is measured by R9, and in display, retail and food spaces it has to be asked for separately.
Colour temperature
K
It sets the character of a space, and there is no correct value, only a decision. Mixing values within one project is the most visible mistake there is.
Colour consistency
SDCM
This is whether two luminaires side by side give the same white. Under 3 SDCM is preferred, and later additions should be specified from the same bin.
Ingress and impact protection
IP and IK
IP covers dust and water, IK covers impact. Outdoors, in car parks and in sports halls, both are asked together.
Efficacy
lm/W
The efficacy of the luminaire is not the efficacy of the module inside it. Compare the figure that survives the optic and the body.
Life and lumen maintenance
L70B50
An hour count on its own says nothing. It is read together with the flux level, the failure fraction and the ambient temperature it was measured at.
Flicker
flicker
Flicker below conscious perception still causes headaches and fatigue, and shows up as banding on camera. Ask about it separately in offices, schools and broadcast spaces.
Driver and dimming
DALI, 1-10V, phase cut
If the dimming method does not match the project's control system, the system fails even when the luminaire is right. Verify compatibility up front.
Ambient temperature
ta
Datasheet figures hold at a stated ambient. At high level, in a closed recess and outdoors, the real temperature is a different number.
Maintenance access
How the replaceable part will be reached is decided before installation. A luminaire nobody can reach is a luminaire that ends the day it fails.

By sector

Colour temperature and luminaire type by space

This table is the readable form of the reference data the calculation assistant runs on. Illuminance and colour rendering follow the EN 12464-1 space categories; colour temperature and luminaire type follow common design practice.

Space Illuminance Colour temperature Colour rendering Suited luminaire
Office, education, circulation
Office, open plan 500 lx 3500 - 4500 K Ra 80 Linear system, Recessed downlight
Meeting room 500 lx 3000 - 4000 K Ra 80 Recessed downlight, Linear system
Classroom 300 lx 4000 - 5000 K Ra 80 Linear system
Technical drawing desk 750 lx 4000 - 5000 K Ra 80 Linear system
Archive, store room 200 lx 3500 - 4500 K Ra 80 Linear system
Corridor, circulation 100 lx 3000 - 4000 K Ra 40 Recessed downlight, Linear system
Stairs 150 lx 3000 - 4000 K Ra 40 Recessed downlight
Washroom, WC 200 lx 3000 - 4000 K Ra 80 Recessed downlight
Retail and hospitality
Retail sales floor 300 lx 3000 - 4000 K Ra 80 Track and spot, Recessed downlight
Checkout, counter 500 lx 3000 - 4000 K Ra 80 Recessed downlight, Linear system
Reception desk 300 lx 3000 - 3500 K Ra 80 Recessed downlight, Project-specific
Lobby, waiting area 200 lx 2700 - 3000 K Ra 80 Recessed downlight, Project-specific, Track and spot
Restaurant, cafe floor 200 lx 2700 - 3000 K Ra 90 Project-specific, Track and spot, Recessed downlight
Commercial kitchen 500 lx 4000 - 5000 K Ra 80 Linear system
Sports hall, training 300 lx 4000 - 5000 K Ra 80 High bay, Linear system
Industry, storage, parking
Rough assembly, fabrication 200 lx 4000 - 5000 K Ra 80 High bay, Linear system
Medium assembly work 300 lx 4000 - 5000 K Ra 80 High bay, Linear system
Fine assembly work 500 lx 4000 - 5000 K Ra 80 Linear system, High bay
Precision assembly, inspection 750 lx 4000 - 5000 K Ra 80 Linear system
Warehouse aisle, staffed 150 lx 4000 - 5000 K Ra 60 High bay, Linear system
Packing, dispatch 300 lx 4000 - 5000 K Ra 80 Linear system, High bay
Indoor car park 75 lx 4000 - 5000 K Ra 40 Linear system
Culture and care
Museum, exhibition hall 200 lx 3000 - 3500 K Ra 90 Track and spot, Recessed downlight
Sensitive exhibits 50 lx 2700 - 3000 K Ra 90 Track and spot
Gallery, art space 300 lx 3000 - 4000 K Ra 90 Track and spot, Linear system
Examination room 1000 lx 4000 - 5000 K Ra 90 Linear system, Recessed downlight

Colour temperature and luminaire type are design decisions, not requirements of the standard. For illuminance and colour rendering, the edition of the standard in force governs.

Let us buildthe spacetogether.

Share your project, your drawings or your technical requirements. We will work out together where the light lands, at what angle and at what intensity.