Lighting calculation assistant
Describe the room and the calculation writes itself
Give the room its dimensions and its purpose. The assistant sets the target illuminance, finds the total flux the room needs by the lumen method, and derives the luminaire count and the layout grid.
Calculation assistant
Four questions. At the end, a requirement sheet you can send to our engineering team.
The assistant runs in the browser and needs JavaScript. Send us your room dimensions through the contact form and we will run the calculation for you.
| What will the room be used for? | Illuminancelx | UniformityUo | Glare limitUGR | Colour renderingRa | Colour temperatureK |
|---|---|---|---|---|---|
| Office, education, circulation | |||||
| Office, open plan | 500 | 0.6 | 19 | 80 | 3500-4500 |
| Meeting room | 500 | 0.6 | 19 | 80 | 3000-4000 |
| Classroom | 300 | 0.6 | 19 | 80 | 4000-5000 |
| Technical drawing desk | 750 | 0.7 | 16 | 80 | 4000-5000 |
| Archive, store room | 200 | 0.4 | 25 | 80 | 3500-4500 |
| Corridor, circulation | 100 | 0.4 | 28 | 40 | 3000-4000 |
| Stairs | 150 | 0.4 | 25 | 40 | 3000-4000 |
| Washroom, WC | 200 | 0.4 | 25 | 80 | 3000-4000 |
| Retail and hospitality | |||||
| Retail sales floor | 300 | 0.4 | 22 | 80 | 3000-4000 |
| Checkout, counter | 500 | 0.6 | 19 | 80 | 3000-4000 |
| Reception desk | 300 | 0.6 | 22 | 80 | 3000-3500 |
| Lobby, waiting area * | 200 | 0.4 | 22 | 80 | 2700-3000 |
| Restaurant, cafe floor * | 200 | 0.4 | 22 | 90 | 2700-3000 |
| Commercial kitchen | 500 | 0.6 | 22 | 80 | 4000-5000 |
| Sports hall, training | 300 | 0.6 | 22 | 80 | 4000-5000 |
| Industry, storage, parking | |||||
| Rough assembly, fabrication | 200 | 0.4 | 25 | 80 | 4000-5000 |
| Medium assembly work | 300 | 0.6 | 22 | 80 | 4000-5000 |
| Fine assembly work | 500 | 0.6 | 22 | 80 | 4000-5000 |
| Precision assembly, inspection | 750 | 0.7 | 19 | 80 | 4000-5000 |
| Warehouse aisle, staffed | 150 | 0.4 | 25 | 60 | 4000-5000 |
| Packing, dispatch | 300 | 0.6 | 25 | 80 | 4000-5000 |
| Indoor car park | 75 | 0.4 | 25 | 40 | 4000-5000 |
| Culture and care | |||||
| Museum, exhibition hall * | 200 | 0.4 | 19 | 90 | 3000-3500 |
| Sensitive exhibits * | 50 | 0.4 | 19 | 90 | 2700-3000 |
| Gallery, art space * | 300 | 0.4 | 19 | 90 | 3000-4000 |
| Examination room | 1000 | 0.6 | 19 | 90 | 4000-5000 |
The standard sets no fixed value for this category. The figure below is a common design starting point and is settled per project. Colour temperature is a design decision, not a requirement of the standard.
Lighting calculation
Light is not estimated, it is calculated
Luminaire count is not a preference, it is a result. Once room dimensions, surface reflectances, mounting height and target illuminance are on the table, the layout writes itself.
- Luminaire
- Beam cone
- Isolux contour
- Illuminance lx
- Light arriving at the working plane. The function of the space sets the target.
- Uniformity Uo
- Minimum over average. It keeps the eye reading the space without interruption.
- Glare UGR
- A measure of uncomfortable brightness in the direct field of view.
- Colour rendering Ra
- How truly colour reads under the light. Decisive in display and retail.
- Beam angle °
- The spread of the light. It separates accent from general lighting.
- Energy density W/m²
- Installed load per unit area. The indicator of efficiency and running cost.